ERD-5850 Series
Key Features
Function
High-Performance Motion Detection
Detection Area
Mid-Mount:
LOS≥10m,Radius 3-6m(Mounting Height 4-6m),FOV: 120°
High-Mount:
LOS≥15m,Radius 3-6m(Mounting Height 9-12m),FOV:120°
Frequency Band
5.8GHz
Output Interface
UART、IO/PWM
Size
20*20mm 28*25mm
Overview
This is a 5.8GHz radar module with built-in strong anti-interference algorithm, featuring stable mobile sensing performance in high-mounting applications. It also has the capabilities of adjustable sensing range and light intensity detection. Its wide application range and strong adaptability make it the preferred choice for creating smart industries, intelligent warehouses, and intelligent lighting fields.
Specifications
| Modulation System | FMCW |
| Antenna | 1T1R |
| Input Voltage | DC 3.3V-12V |
| Operating Current | 11mA at DC 5V |
| Operating Temperature | -20℃ to 85℃ |
Download
FAQs
Why does the module keep lighting up or going off frequently?
1. Check if the output circuit of the module's O port is properly connected to a forced pull-up or pull-down;
2. Check if there is any short circuit on the three pins of the module;
3. Check if the power supply's load capacity can cover the current specified by the module.
Does it have a light-sensitive function?
All models can be equipped with the light-sensitive function, and the parameters can be adjusted.
Can it be dimmed?
The module can output PWM signals for dimming.
Why does the module not output when the device is within the reference detection range?
This series of modules are for detecting mobile signals. If the movement of the target within the detection range is very small (such as standing still/ sitting still/shaking head/using a mobile phone, etc.), it may not meet the conditions to wake up the module.
Are there any special requirements for the electrical parameters of the power supply?
Power supply design should follow the EMC design requirements, control the ripple size less than 150mv, as far as possible to reduce the power frequency signal (50Hz) energy amplitude (try to control below -30dBm), the input voltage to the module should strictly follow the module specification requirements.
Are there any special requirements for module installation?
1. Near the installation position of the module, avoid placing large capacitors, inductors, transformers, rectifier bridges and other components that perform voltage and current conversion. Otherwise, the generated electromagnetic radiation may affect the detection stability of the module.
2. The installation height of the module should not be lower than the height of the surrounding components. If the structure is restricted, adjust according to the actual test results.
3. The module should be installed horizontally to ensure the uniformity of the detection range.
4. The product to which the module is applied should preferably be made of non-metallic materials. If the product has metal components, adjust the application parameters of the module based on the actual test results.
Will the modules affect each other? Can they be tested adjacent to each other?
Modules will affect each other. If multiple devices need to be tested at the same time, a distance of more than 1m should be kept apart, and the sensing surfaces of the modules should be staggered.
Why is the module not responding sensitively or giving false alarms?
Please check if the requirements of A5 and A6 have been met during the application process.
Why did the module not respond after the protocol was sent?
Please check if there are any errors in the protocol content sent and if the baud rate was selected correctly.
The output pins of the module are not clearly defined. What exactly is the output?
The TX pin and OUT pin on the module are shared. By default, it is the OUT pin that outputs. The function of the pins can be switched according to the protocol. Alternatively, you can choose a module without the re-mapping function. We offer the option of software versions as well.
For more detailed questions and answers, please contact our technical staff.